Chinese Journal of Geriatrics ; (12): 798-802, 2021.
Article in Chinese | WPRIM | ID: wpr-910921

ABSTRACT

Population aging increases the demand for human aging research and its clinical applications.Traditionally, the chronological age(CA), that is, the age based on the calendar, is used to describe the state of aging.However, the aging process and speed among individuals are not consistent and often show clear individual differences in biological aging.Therefore, CA cannot truly reflect people's conditions of body structure and function, has drawbacks leading to unreliable and wrong assessment, and is unable to accurately describe the human body's state of aging.In recent years, it has been proposed that the biological age(BA)should be used to more comprehensively and accurately describe the stage of human aging.Combining mathematical algorithms with a variety of biomarkers, predictive models can be constructed to quantify BA.These approaches have been increasingly appreciated for their improved accuracy and received further investigation.This article reviews the value of BA, currently commonly used calculation methods and their progress and prospects in healthy aging.

2.
Chinese Journal of Geriatrics ; (12): 976-980, 2020.
Article in Chinese | WPRIM | ID: wpr-869509

ABSTRACT

Elevated levels of circulating branched-chain amino acids(BCAA)increase the risk of cardiometabolic diseases(CMD)and may be a new risk factor for CMD.However, BCAA have been used as dietary supplements to promote health in clinical nutrition and medicine.BCAA are essential amino acids that must be acquired from food sources.Whether BCAA supplements can cause elevated circulating BCAA levels and consequently lead to CMD is still controversial.Recent studies have found that the roles of BCAA may vary under different conditions such as energy excess, energy deficiency and energy balance.This article reviews recent advances in research on BCAA and CMD.

3.
Chinese Journal of Geriatrics ; (12): 352-356, 2020.
Article in Chinese | WPRIM | ID: wpr-869374

ABSTRACT

Mendelian randomization is a genetic epidemiological method for confounding adjustment of cross-sectional data by introducing genotypes as instrumental variables of exposure factors and possesses unique advantages for the adjustment of unmeasured and unknown confounding factors.In recent years, Mendelian randomization has been widely used and achieved rapid progress in the etiology research of common diseases in the elderly.This article reviews this method and its application in these diseases, including cardiovascular disease, type 2 diabetes mellitus, osteoporosis, Alzheimer's disease and malignant tumor.

4.
Chinese Journal of Laboratory Medicine ; (12): 623-628, 2019.
Article in Chinese | WPRIM | ID: wpr-756479

ABSTRACT

Objective To propose and validate a reduced volume β-quantification method to measure serum high-density lipoprotein cholesterol (HDL-C) and low-density lipoprotein cholesterol (LDL-C). Methods The reduced volume β-quantification method involved separation of LDL and HDL by ultracentrifugation and preparation of HDL by chemical precipitation. The sampling and reconstitution of the bottom fractions were performed gravimetrically and sample volume was thus decreased from 5 to 0.8 ml. High performance liquid chromatography was used to determine the cholesterol concentration of bottom fractions and HDL-C in the supernatant. Serum levels of LDL-C depended on a calculation of bottom fractions cholesterol minus HDL-C. Results The total CVs for HDL-C and LDL-C were 0.65% -1.75% and 0.63% -1.11%. The results of the developed method were consistent with the current reference method and well within the allowable bias for Cholesterol Reference Method Laboratory Network surveys. Conclusion A new method for the measurement of HDL-C and LDL-C has been established. This method requires a small amount of serum and is easy to operate, exhibiting a desirable precision and accuracy. It is reliable and can be used as a candidate reference method for HDL-C and LDL-C.

5.
Chinese Journal of Laboratory Medicine ; (12): 103-108, 2018.
Article in Chinese | WPRIM | ID: wpr-712110

ABSTRACT

Objective To establish a method for measuring blood phosphatidylethanol by liquid chromatography coupled with tandem mass spectrometry(LC-MS/MS), which can be applied for objective and quantitative of alcohol intake.Methods Whole blood samples were treated with isopropanol to precipitate protein,and phosphopropanol(16:0/16:0)was used as the standard.After centrifugation, the supernatants were transferred and evaporated under a stream of nitrogen until dryness.Then the residuals were analyzed by LC-MS/MS.Various methodological parameters, including linearity, limit of detection (LOD), limit of quantitation(LOQ), recovery, and precision, were investigated.Finally, blood samples from 40 Chinese individuals with more than one year of regular drinking habits were analyzed, and distributions of phosphatidylethanol were evaluated.Results The correlation coefficients were higher than 0.9992.The LOD and LOQ were lower than 0.74 and 2.48 ng/ml, respectively.The inter-and total assay coefficient of variations were 0.77%-3.18% and 2.30%-6.95%, respectively, with recoveries ranged from 96.88% to 102.99%.The relationship between phosphatidylethanol level and self-reported alcohol consumption was significantly and positively correlated(r =0.769, P <0.001).Furthermore, Kruskal-Wallis analysis showed a significant difference in total phosphatidylethanol levels among individuals with different levels of alcohol intake(χ2=18.850,P<0.001).Conclusions An LC-MS/MS method for whole blood phosphatidylethanol detection has been developed.This method is simple,sensitive and accurate and can effectively reflect light,moderate and heavy alcohol intake.The method will be applied to the assessment of alcohol consumption and its association with the risks of drinking related diseases.

6.
Journal of Modern Laboratory Medicine ; (4): 21-24, 2016.
Article in Chinese | WPRIM | ID: wpr-487871

ABSTRACT

Objective To examine the stability of high-density lipoprotein cholesterol (HDL-C)during serum incubation at different temperature and time periods.Methods Ten healthy volunteers (4 males and 6 females,aged 24 to 59 years)from Beijing Hospital were recruited in May 2015.Fasting venous blood samples were collected and centrifuged to separate the sera.Serum samples were incubated at 4℃ for 24 h,25℃for 0,1,8 and 24 h (with or without an LCAT inhibitor).Serum to-tal cholesterol (TC),total free cholesterol (TFC)HDL-C and HDL-FC were measured by the HPLC Method.Results HDL-FC and HDL-C changed -6.91% and -2.17% during serum incubation at 4℃for 24h.TFC,HDL-FC and HDL-C changed significantly (averaged -13.70%,-25.88% and -1.53% respectively)during serum incubation at 25℃ for 24 h,in which the decrease of TFC and HDL-FC were inhibited by the addition of the LCAT inhibitor.The decrease of HDL-C was even higher in the presence of the LCAT inhibitor.Conclusion Serum TFC,HDL-C and HDL-FC levels changed during serum incubations,which were caused by the LCAT and CETP activities and the transfer of cholesterol among lipoproteins. For accurate measurement of serum HDL-C,prolonged serum storage should be avoided in clinical laboratories.

7.
Chinese Journal of Laboratory Medicine ; (12): 178-182, 2015.
Article in Chinese | WPRIM | ID: wpr-474429

ABSTRACT

Objective To develop a solid phase extraction and Folin-Ciocalteu method for the measurement of total polyphenols in urine samples.Methods From a group of individuals attending an annual physical examination at Beijing hospital, 123 healthy volunteers (52 males and 71 females, ranging in age from 18 to 81 years ) were recruited during the period from December 2013 to April 2014.Urine samples were stored in 0.5%HCl at -80 ℃.For analysis, samples were applied to the Plexa PAX solid phase extraction cartridge, to purity the polyphenols through washing, evaporating and reconstituting.Total polyphenols were measured by Folin-Ciocalteu colorimetric assay, calculated by gallic acid standard curve, and corrected by urine creatinine concentrations.The relationship between total polyphenols and fruits and vegetable intake and cardiovascular disease risk factors were analyzed. Results Gallic acid standard solution and urine samples were stable in 0.5% HCl for 48 h at RT and 7days at 4 ℃, respectively.The PAX cartridge effectively eliminated the possible interfere materials in urine and had better recovery for most of the polyphenol types.The inter assay and total CVs for the measurement of total polyphenols were 2.7%-3.8% and 2.4%-4.6 %, respectively.Total polyphenol concentrations of 123 healthy subjects were 114.13(82.97-146.70) mg GAE/g Crea.Total polyphenol levels positively correlated with both HDL-C (r=0.194, P=0.032) and apoAI (r=0.312,P<0.001), and negatively correlated with serum uric acid levels(r=-0.220,P=0.014).Conclusions We established a measurement of total polyphenols in urine samples using solid phase extraction and Folin-Ciocalteu method.This simple, precise method reliable and may be use to assess dietary polyphenols intake.

8.
Journal of Zhejiang Chinese Medical University ; (6): 1324-1325, 2013.
Article in Chinese | WPRIM | ID: wpr-441012

ABSTRACT

[Objective] To observe the clinical effect of applying wet union principle in saccharose treating pressure sores.[Method] Randomly divide 44 cas-es into treatment group 25 cases and control group 19 cases. Both groups were actively treated with primary diseases, the control one with hydrogen per-oxide, NS and traditional therapy of iodine; the treatment one added with saccharose applied on surface of sores; 1m as a course, after 1 course, compare their treatment results.[Results] In treatment group, the total effective rate, treating period and times al were al better than control group, the difference of the comparison had statistical meaning.[Conclusion] Adding saccharose to treat pressure sores can cure the sores surface more quickly and shorten the treat-ing period, is the ideal method for pressure sores.

9.
Journal of Zhejiang Chinese Medical University ; (6): 1002-1004, 2013.
Article in Chinese | WPRIM | ID: wpr-438328

ABSTRACT

[Objective] To observe the cure effect of atropine micro pump sustainable intravenous injection on organic phosphorous pesticide poisoning. [Method] Select 100 such cases taking atropine, divide them into treatment group(micro pump sustainable intravenous injection, 30 cases) and control group(interval intravenous injection, 70 cases); the atropine administration was revised according to poisoning degrees. [Result] The treatment time of atropinzation for treatment group was (6.78±1.89)h,and (9.09±2.79)h for control one;the poisoning rate in treatment group was 6.67%, the cure time (14.08±3.59)h;they were respectively 27.14%,and(16.49±4.58)h for control one;their differences were of statistical meaning and marked statistical mean-ing respectively by comparison. [Conclusion] The treatment above can increase the cure effect and effectively reduce poisoning rate.

10.
Chinese Journal of Laboratory Medicine ; (12): 333-338, 2012.
Article in Chinese | WPRIM | ID: wpr-428795

ABSTRACT

Objective To establish a method for measuring serum cotinine by isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) and provide an assay that can be applied to theevaluation of the level of smoke exposure and to the risk analysis of smoking related diseases.Methods Blood samples were collected from 94 apparently healthy subjects from October to December in 2010 and centrifuged,and the sera were separated.Serum samples were mixed with [ D3 ] -cotinine ( as the internal standard) and treated with acetonitriles to precipitate protein.After centrifugation,the supernatants were transferred and evaporated under a stream of nitrogen until dryness and reconstituted with mobile phase.Then the residuals were analyzed by LC/MS/MS system with multiple reaction monitor model; the concentration of cotinine were quantified by the isotope internal standard method and the stand curve was employed with a series of calibration.To estimate the precision of the method,five frozen serum pools were repeatedly analyzed in five runs,and every pool was analyzed in triplicate.In addition,the recovery rates were analyzed with the serum sample added with different levels of standard.The stability of cotinine in serum preserved at room temperature,4 ℃ and - 80 ℃,respectively.Finally,the levels of cotinine of 94 healthy subjects were measured to evaluate the distribution of cotinine with different smoke statuses.Results Serum cotinine measured by ID-LC/MS/MS was separated well with few interferences.The correlation coefficients between the peak area ratios and cotinine concentrations were higher than 0.9993.The values of within-run coefficients of variation (CV) of five frozen serum pools (0.68,48.42,94.34,250.95 and 287.04 μg/L) were 2.19%,0.78%,0.75%,0.65% and 0.67%,respectively.The values of total CV were 4.71%,1.40%,1.98%,1.10% and 1.03%,respectively.The limit of detection (LOD) and limit of quantitation ( LOQ ) were 0.013 and 0.050 μg/L,respectively.The analytical recoveries ranged from 99.22% to 102.67%.The samples could maintain stability within 2 d at room temperature,7 d at 4 ℃ and 3 months at -80 ℃ resulting the accuracy of measurements from 99.28% to 100.87% and the CV<5%.The levels of cotinine of 94 healthy subjects were measured and shown skewed and leptokurtic distribution.The concentrations of twenty smokers,fourteen former smokers and sixty non-smokers were 116.40 (63.17 -241.12),0.67 (0.15 - 0.95 ) and 0.22 (0.15 - 0.42 ) μg/L,respectively.Furthermore,the level of cotinine of former smokers (Z =-2.12,P <0.05) and smokers (Z =-6.67,P <0.001) were statistically higher than non-smokers.Conclusions An ID-LC/MS/MS method for serum cotinine detection has been established.It is hoped that the method will be applied to the assessment of smoke exposure and its association with the risks of smoking related diseases since it is simple,specific,precise,sensitive and accurate.